There’s the old saying about ‘not being able to see the forest for the trees’. Lately, I’ve been so busy posting about the goings on at the Beta Site that I’ve pretty much ignored the other things going on in this world. I mean, look at the blog posts before I got the Beta Site…then look at the posts after. Big change in content and frequency of particular types of content.

It was kind of to be expected, I think…but that sort of narrowed vision is not going to do anybody any good. There’s the increasing chances of Big(ger) Bad Things happening on the international level, Socialists are actually starting to win elections that matter, inflation is continuing, and there’s just a more pronounced mood of uncertainty. But, thus far, all those ‘funny feelings’ about the current situation, going as far back as the beginning of this blog, have turned out to not really lead to anything. But, thats no guarantee that things will ‘work out’ this time.

Believe it or not, the Beta Site has actually lowered my level of preparedness. How, you may ask? Easy. My primary residence, which contained 100% of my preparations against the uncertain future, now contains a good bit less since a bunch was moved to the Beta Site….which means I went from one location that was 100% of what I thought I needed, to two locations that each had less than 100% of what I needed. Thus, being at either location is an exercise in being less prepared than I was when I had just the one location.

I need to ‘re-stock’ my main residence on some of the things I’ve moved to the Beta Site. Mostly things like tools, clothing, camping gear, and that sort of thing. But, for example, my Sawzall is up there which means I am without a Sawzall down here. What I’ve been thinking of doing is keeping the cordless stuff at the Beta Site an keep the corded stuff down here. Milwaukee M18 7.25″ circ saw? Goes to the Beta Site. Makita corded 7.25″ circ saw? Stays here in town.

One thing that is definitely non-negotiable is that I need to pick up another Honda EU2000. I cannot be without a generator here in town. The risks are too high. A generator in town is generally just relegated to emergency use, a generator at the Beta Site will get a good bit more use since there’s no electric up there. As a result, right now, the generator sits at the Beta Site, leaving my primary residence without.

Since winter is going to be a time of minimal development at the Beta Site, I’ll be using the time to financially heal up and get ready for next year’s big purchases – well and septic. I was lucky this year in that the Beta Site was able to ‘open for business’ around the beginning of May. Im going to lan on a June 1 “opening day” up there but I suspect I’ll be able to get in there and do stuff before then. But for financial planning purposes, Im going with June 1. That gives me about 24-28 weeks of no major activity at the Beta Site to heal from this years expenditures and save up for next years.

In the meantime though, definitely gotta fill in the gaps here at the primary residence.

26 thoughts on “Forest for the trees”

  1. We can only do as much as we can do. The fact that you actually HAVE a beta site puts you MILES ahead of me, but I’m STILL better prepared than 98% of the people around me.

    The EU2000i is a small genny. Why can’t you keep it wherever you are living at the time? That being said, having only one genny where you live is a risk in itself. I’ve had several instances where a well maintained, quality genny malfunctioned in a major way for no apparent reason at all. I’m talking “This one’s down until I can get the parts.” That’s “down for good” in prepper terms. Yeah, the backup genny could be Chinesium (Harbor Freight), but at least it would be available. In my case, my whole-house genny is backed up with a 5Kw Subaru portable that’s “dry stored.” It won’t run the whole house, but will run the essentials…

    • 2000 watt is really small for a home,keep your eye out for a quality 5000(+/-?) Watt used low hour unit. That gives you plenty of power without being too big. Right size to camouflage with a “dog house” for storage. Put a water bowl and LARGE CHAIN with it and a prowler might decide he has better places to be

    • Harbor Fraud changed tactics a while ago. Moved toward quality a shorted it’s supply chain. HF Predator gensets are considered quite good. With the liberal return policy good low hour units can be had quite reasonably. If you make friends with store Manager and let him know what you want a unit from warehouse or other store could show up quickly at a good price. A unit properly covered,wired in( grid disconnect) and ready to go could be a real selling point when Alpha site goes surplus

  2. Sounds like a plan.

    We could be shuffling to a near term disaster by this October. No sure why but a feeling more than anything.

    Have to see. Who knows, this could be the good old days someday.

  3. In line with not spending more for a bit, maybe haul the little genny to and fro until you buy #2? Or is it more cumbersome than I realize or there is some glaringly obvious factor I’m overlooking?

    • Im trying to establish a setup where I don’t have to bring anything to the Beta Site in a crisis except my tired and panicked self. Financially, and logistically in this moment, it makes sense to bring the generator back and forth, but the end goal is to have things setup so that I can just show up with the clothes on my back and whatever I need is already in place. But…maybe back-n-forth is the way to go for now.

  4. Have you thought about getting a dual fuel genny vs the Honda. I really don’t get why Honda doesn’t have dual fuel options. The cost for Honda is bad enough but only limited to gas is a bit much. Had a couple friends who had Honda’s and several other brands during the NC hurricane floods and now they have changed to other brand dual fuel models. Not just for the fuel options but for issues that popped up from long term usage that other brands had also, like the CO2 detectors are way too sensitive to unit placement, sensor failures, etc, so why pay the extra for the same limitations? No one is making things to last like they used to and lots make the same products in the same chinese factories but just have different names on units, and that applies to the big name companies..

    • I like the Honda for its reputation and aftermarket support. There are kits out there to make it tri-fuel (nat gas, propane, gasoline) and a gas/propane conversion is definitely in the cards since at some point there’ll be a big ol’ propane tank up there.

    • I have the bigger version, the EU3000i and I like it a lot. But it’s twice the size of the EU2000i and still doesn’t do 220v… The propane conversions are easily available and simple to install. There are varying levels of integration and fit and finish to match your goals and pocketbook. Consider how the kit deals with the regulator, and the input hose to the genny.

      It also may be that the kits for the 3000 are so well developed because it has a serious flaw where the gas tanks rot out, and an internal gas filter that swells and clogs, WHEN IMMERSED IN GASOLINE! So…

      I no longer run my 3000 on anything but propane.

      That said.

      You get slightly decreased max load when on propane. You lose the “eco throttle” adaptive throttle function. You have to have the bottle attached with the hose, and the regulator, and that is not compact or convenient to move. The best part of the “suitcase” inverter gennies is the compact completeness of the unit. Grab the handle, move it, fire it up. The propane conversions SIGNIFICANTLY lower that convenience.

      You can counter that with more extension cords… and just leave it sitting in an out of the way location.

      At the end of the day, dual fuel gives you more options, but there are always trade offs. My EU3000i gennies have become single fuel — propane — because the conversion kit is cheaper than a new tank.

      Hope there is something useful in this note.

      nick

      BTW, I have gennies at home and at the BOL. And if you look at the EU3000i for a bit more capacity, get the wheels.

  5. ‘Nother reason why two is one and one is none. 😉

    BTW
    Buy it while it can be bought means:
    1. It’s still on the shelf, but more importantly,
    2. You can still use our fiat currency to buy stuff.

  6. Consider a dry well for gray water, sure it’s more plumbing to separate the gray water from the black water. In the end you end up with a smaller (500 gal) septic tank and smaller field. Another possibility is a composting toilet. Years back I wanted to put a small cabin on a corner of a family property. It was right on the river and the MI DEQ said no way even though it would have been zero discharge in to the ground. Arrogant government employees, wouldn’t even look at other solutions like composting or incinerating toilets. Sold the house and property back in 2017. Man I miss that place.

  7. Interesting to hear your tone on current events. Maybe its age or over-focus on 2A, but I am seeing hope on the horizon with the restoration of civil rights that are occurring. A forced work-trip to Houston restored my appreciation for our personal preparations compared to the city people. And it became casually clear that those of us in attendance who were not the two obvious urban lefties; were all very similarly, albeit independently, of similar minds. Odd topics in careful casual conversation were about hunting, trucks, radio, construction. Then driving home, I saw a stranger/neighbor checking his mail wearing a ‘right wing’ tee-shirt. Just some random guy who maybe I need to say hi to. The trip and coming home renewed my faith in that quote about behind every blade of grass. Of course this does not effect preparations – but maybe the doomsday clock is at 10 minutes until the hour, not whatever the loonies are trying to scare us with. Now back to cleaning the new, unneeded S&W I just bought….

  8. We have been very happy with our tri-fuel gen (elect start) set that we got at costco. It lives in the pump house to provide water during usually, winter outages. It has proven to be very reliable on propane. The other gen set is gasoline only, an onan and reliable also. I should sell it and get another tri fuel. Two is definitely one at times. I should check into an EMP cover of some sort, the cloth maybe?

  9. I have two Hondas and a Champion, and my sister has a dual-fuel Champion. I think if you’re not going to rack up a huge number of hours, a Champion is fine.

    For a generator that isn’t being used regularly, the benefits of running on propane are even greater. Both for keeping the carb clean, and ease of long term fuel storage.

    One thing that eventually wears out on a gennie is the pull starter rope. Spare rope is cheap, or even a complete recoil starter assembly.

    I overwintered once in a friend’s cabin in snow country. At temps below freezing, his Honda 2000 would start but then do a low oil shutdown, not due to low oil but because of thick oil. I’d have to start it a few times to make it keep running. I ended up storing it indoors.

  10. Generator – if it’s not going to be moved much, consider an EU3000 for home; Honda used to make a wheel & handle set for those, no longer available but some EU3000 models come with wheels now. It’ll cost more – about $800 above a 2000 – and isn’t as portable but delivers 50% greater capacity and it’s significantly quieter and has a bigger fuel tank than a 2000 (1.25 gallons for a 2000, 3.25 for the 3000).

    For both installations it would be worthwhile to start looking for deals on large gauge extension cords and for the 3000, a “distribution box.” The 3000 is 120 VAC only, so 3-conductor SO works well; I built mine with 135 feet of 10-3, L5-30s on both ends (the 3000 has an L5-30R twist lock), and then used another 25 ft of 10-3 to make a distribution box – an L5-30P on one end (connects to both the female end of the 135 ft 10-3 and the L5-30R on the gennie), with an 8-gang box on the other; all 8 duplex receptacles are 20 amp rated, 2 of the receptacles are GFCI, each independently wired so if one trips the other doesn’t), and 4 non-GFCI, all 4 receptacles are labeled as to what they are (in case there’s someone who cannot tell the difference between a GFCI receptacle and a non-GFCI).

    IF one is planning for every eventuality, you could use 10-4 which is 4 conductor in case you wanted to run 240 volts somewhere; run 4-prong twist locks on each end (L15-30R and P) and Amazon sells adapter cables to go from 4 conductor to 3 (they also sell 3-to-4 adapters so you can use 3-conductor to supply 4-conductor inputs; it halves the amps per side, but half is better than zero). I built a 4-conductor with 130 ft of 8-4 because I’ve got a 7K Honda that puts out 240; 130 ft of 8-4 ain’t a bit cheap and the coil is damn heavy (if you can get by with 100 ft of 8-4 Home Depot used to have a deal on it, but if you want more than 100 ft now you’re paying for each foot, so get friendly with wholesale electrical equipment suppliers). If you do ever have 240 VAC, it’s useful to make a distribution box for it – 10-20 ft of 8-4 with an L15-30P on one end and 2 X L5-30Rs in one metal box and each on one leg of the 240 so you can run the 8-4 from the gennie to Point X, then connect a 4-gang 120 VAC distribution box to each side. (Pro tip: if you’re putting a code-approved L15-30 connection on the house to feed generator power in, at the same time put in a separately breakered L15-30R on the output side to also feed 240 VAC out; it’ll be handier than you think).

    Gray water – costs more to put in because it requires a 2nd tank and leach field, but “good” gray water can be used for irrigating plants, black water cannot. One advantage is taking the gray water load off the sanitary system reduces its size and keeping the soaps and anti-bacterials, etc. out of the sanitary system benefits the bacterial decomposition of the tank contents.

  11. While the Honda 2000 generator is good, check its amperage rating its good for 13 amps while a Predator is about 20 amps or so, my Honda 2000 generator can’t handle a 110 volt wood chipper, I have to use either a larger gen or 11o volts from the house.

    • Having a small welder at the remote site would be very useful. There seems to be a lot of 110/220 welders available now. Bought one a couple years ago, a MIG that could fit inside a suitcase. Uses wire with a core of flux, so no need for a tank of inert gases. Can stick weld, and can also TIG with additional accessories. One needs to check that the welder can work with the on hand gen set. I think they are intended for a 20 amp 110 circuit, but I have used a 15 amp for light duty welds. The wire feed is amazing! No bird-nesting! Cost was about $400 then.
      I see one day classes to learn welding being listed now.

  12. I think you may be evaluating in a different paradigm. You are actually far more prepared as location diversification has made point failure far less problematic. If Alpha goes catastrophic you have Beta and vice-versa ( kinda the point?) . Just because levels at one point decline overall the supply total remained constant. No longer having to ride out in one location gives flexibility to supply levels and survivability factors. Just a differing point of view and living through a home fire and watching a lot of preps destroyed changed perspective. BTW conex is great investment but build shelves in before it gets too crowded.

Leave a Reply